BWD Series

Steam outputs from 1500 kg/h to 8000 kg/h
The BWD series of fire tube steam boilers feature three pass design and use a coaxially located furnace tube providing optimum distribution of mechanical stress in operation. This is a key feature for boilers that operate under low or variable steam load and ensures long equipment life. High quality dry steam is provided due to generous steam space and integral separator.

Low Fuel Consumption

  • The perfect match between the boiler shell and burner ensures reliable and efficient operation. Efficiencies of 95% plus can be achieved when fitted with a Babcock Wanson matched economiser and heat recovery system.
  • Consistent high thermal efficiency throughout the firing range is a key feature. Digital micro-modulation control with burner head geometry specifically designed to suit the BWD boiler means accurate control of excess air and lowest practicable operating costs.
  • Electrical power consumption can be reduced by 30% to 50% by the use of variable speed control for the combustion air fan and feed water pump when specified.

Reduced Operating Cost

  • Robust Construction for long life
  • Direct access to the reversal chamber and ease of tube inspection simplifies mandatory inspection
  • The outer walls of the flue gas reversal chamber are water cooled and provide high efficiency without the need for furnace tie rods which can be a weak point on traditional wet back boilers
  • Standard equipment options include fully approved controls for attended, site supervised or fully unattended operation including the Babcock Wanson BW720 Operating System.

Why Choose the BWD Fire Tube Steam Boiler?

  • Efficiency – Low NOx burners
  • High burner turndown ratio
  • Simple access for ease of maintenance
  • Robust design for very long life
  • Flue gas and condensing Economisers
  • Combustion air Pre-Heaters
  • Dual and mixed fuel firing options
  • O2 and CO trim options
  • Simple unattended operation
  • Complete steam system solutions

BWD Series Fire Tube Steam Boiler

BWD model 15 20 25 30 35 40 50 60 70 80
Steam output (1) Kg/h 1500 2000 2500 3000 3500 4000 5000 6000 7000 8000
Power output (1) kW 2025 1366 1707 2049 2390 2732 3415 4097 4780 5445
Width A (2) mm 2145 2145 2230 2230 2360 2360 2660 2660 2890 2890
Length B (2) mm 4630 4630 5950 5950 6980 6980 8030 8030 8640 8640
Height C (2) mm 2450 2450 2630 2630 2730 2730 3090 3090 3515 3515
Weight-fully flooded Kg 10200 10200 12500 12500 16300 16300 24800 24800 33700 33700

(1) At 15 barg and feedwater at 80°C

(2) Overall diamensions include fitted burner and boiler mountings