Martindale-Pharma boiler

Martindale Pharma

Babcock Wanson has supplied two 2000kg/h VPX Rapid Steam Generators to Martindale Pharma, a market leader in the manufacture and supply of specialty pharmaceuticals and services for healthcare professionals worldwide.

Martindale-Pharma

Steam Generators for Pharmaceutical Manufacturing

The two Steam Generators have been installed at Martindale Pharma’s principle site of manufacture in Romford, Essex, which specialises in the production of sterile ampoules, sterile screw cap bottles, non-sterile liquids, non-sterile suspensions and suppositories.

Steam is produced for a wide variety of uses across the Romford site, including the manufacturing production processes, production of Water for Injection (WFI) and a Pure Steam Generator (PSG), as well as heating for the company’s Air Handling Systems. The new VPX units have replaced four smaller generators that were unable to meet Martindale Pharma’s growth and subsequent capacity requirements.

VPX Vertical Coil Steam Generators

VPX vertical coil Steam Generators from Babcock Wanson feature three full gas passes plus an in-built combustion air pre heater to give high operating efficiency. With availability of steam from cold start in as little as three minutes and a low volume of water under pressure the VPX Steam Generator combines efficiency with safety, even at very high working pressure. They are rugged in construction and very compact.

The pressure containing coil design of the VPX Steam Generator forms the main combustion chamber with the second and third passes for the gasses going between the coil windings to ensure high gas velocity with good heat transfer and self cleaning of the smoke side. Accurate flame dimensions are important for any combustion device and the use of a purpose built and matched Babcock Wanson burner ensures long life and simple operation. The feed water system is simple in operation and easy to maintain, consisting of either a multi diaphragm type positive displacement pump driven from an inverter controlled motor for both accurate control and lowest electrical demand.

As there is no discernible water level with a coil type boiler, the need for water level gauge glasses and other devices normally associated with fire tube boilers is eliminated with the associated reduction in boiler house manning demands. This equals simple and safe operation at the lowest practicable operating cost.

Martindale-Pharma1
Martindale-Pharma2

More than just an Installation

To maintain the Steam Generators’ efficiency and maximise their working life, Martindale Pharma has signed up to Babcock Wanson’s Water Treatment Service operated in conjunction with water treatment specialist Deep Water Blue. Under this service Martindale Pharma benefits from the deployment of highly qualified, professional chemists who ensure the treatment and testing regime is completed to obtain an accurate picture of the site’s specific requirements under a variety of conditions; this ensures the most appropriate chemical dosing regime is always employed. In between scheduled consultancy visits the unique vSteam® web portal allows Martindale Pharma to simply enter daily readings on-line and receive real-time feedback support.

Mark McLean, Engineering Team Leader at Martindale Pharma, is very pleased with the service; “the service from Deep Water Blue has so far been really good and the internet based reporting system is a fantastic tool for daily feedback on the water conditions, with instant advice on what to do to rectify any reading starting to drift out of specification.”

In addition, the Babcock Wanson Water Treatment Service provides a five year corrosion warranty on the steam generator coil. In the unlikely event of feed water deficiencies causing the coil to corrode within the first five years, Babcock Wanson will replace it under warranty.

Customer Testimonials

Sam Robinson, gerente de engenharia e manutenção de Plantas, Gurit Composite Components

"As caldeiras de fluido térmico são bem fabricadas, de fácil manutenção e têm revelado um bom desempenho. Temos uma unidade instalada, que tem operado aproximadamente 24 horas por dia, 360 dias por ano. Os comandos são de simples leitura, sem inclusão de complicadas funções; São equipamentos fabricados para fazer o que é necessário e funcionam muito bem".

Andrew Taylor, director da cervejaria Freedom Brewery

"Escolhemos o fluido térmico porque é mais barato de instalar e operar, e tem uma pegada ecológica menor do que o vapor, o que oferece uma solução mais amiga do ambiente".

Duncan McLeod, gerente de engenharia, Total Bitumen Preston

"Os principais benefícios que já alcançados com os aquecedores EPC, consiste numa redução de custos em combustível e nas emissões de efluentes gasosos, bem como um aumento significativo da eficiência, além da mudança para o gás natural, ao invés do combustível pesado, que nos permitiu eliminar a necessidade de armazenagem local de combustível".

Jeff Farey, gerente de manutenção, Beardow Adams

"Os geradores de ar quente Babcock Wanson, provaram ser de confiança em toda a nossa empresa (e) sempre nos prestaram um bom serviço".

David Drewry, director técnico da AIM Composites.

"Nunca trabalhámos antes com a Babcock Wanson, mas achei o serviço da mais alta qualidade".

Nicola Lord, director de fábrica , Blackburn Chemicals

"Deparamo-nos com equipamentos eficientes e fiáveis, e recebemos sempre um bom serviço da parte da Babcock Wanson".

Keith Netting, gestor de desenvolvimento de produtos e industrialização, Gurit Composite Components

"As caldeiras de fluido térmico são bem fabricadas, de fácil manutenção e têm revelado um bom desempenho. Temos uma unidade instalada, que tem operado aproximadamente 24 horas por dia, 360 dias por ano, com apenas uma avaria em oito anos; São equipamentos fabricados para fazerem o que lhes é solicitado e funcionam muito bem".

Allan Goulden, director técnico do Eco-Oil

"A redução dos custos energéticos esteve no centro da nossa decisão. Sabíamos que poderíamos conseguir poupanças significativas se passássemos do vapor para o fluido térmico, como fonte de calor para o nosso processo. Estudámos exaustivamente as opções e decidimos que a Babcock Wanson, oferecia a melhor solução. Até agora, provamos estar certos: S sistema reduziu os nossos custos energéticos e é fácil utilização com um bom controlo."

Douglas Watt, engenheiro de processo sénior, Eastham Refinery Ltd

"Os geradores corresponderam às nossas expectativas e são simples utilização. Permitiram uma redução significativa no custo do combustível em relação aos nossos geradores anteriores a óleo".

Peter Shrimpton, director de projectos de engenharia da Bridgnorth Aluminium Ltd

"Não estávamos familiarizados com a Babcock Wanson, mas não tivemos qualquer tipo de problema; basta ligar e po-lo a funcionar é tão simples como isso! O serviço que recebemos da Babcock Wanson, também tem sido excelente".

Ligue-me de volta...

Todos os aspectos no design, organização e serviços dos nossos produtos, são orientados para as necessidades dos nossos clientes.